pid lcd display 0-10Vdc with RS485 modbus temperature controller

FOB Reference Price:Get Latest Price
US $18.8-25 / Pieces | 5 Piece/Pieces (Min. Order)
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Fujian, China (Mainland)
Brand Name:
MAXWELL
Model Number:
FT200
Usage:
Industrial
Theory:
Temperature Controller
Accuracy:
0.3
Temperature range:
0-1800℃
Display:
LCD
size:
48mm*48mm
Color:
white and black
Input:
TC/RTD/analog
output:
relay/ssr / analog
alarm:
1
power supply:
85-265Vac
warranty:
12 months
SupplyAbility
SupplyAbility:
10000 Piece/Pieces per Month
Packaging & Delivery
Packaging Details
maxwell standard package
Port
xiamen
Lead Time :
3-12working days
Video Description

FT20X Ordering Information:

FT20X-X-X-X-X-X-X-X-X-X-X-X 
Default input: TC/RTD  ( Analog input also in optional)
1: Size048mm*48mm(width*height)
448mm*96mm(width*height)
596mm*48mm(width*height)
772mm*72mm(width*height)
996mm*96mm(width*height)
2: Control typeUStandard PID type
PRamp and soak mode(with timer)
XMotor valve direct/reverse control version(two relays)
3: Output 1RRelay output
VSSR Drive/Voltage pulse output
D4-20mA output
E0-10Vdc
F0-20mA
50-5Vdc
71-5Vdc
TTraic single phase zero-crossing trigger
ARelay output, for motor valve direct act control
4:Output 2     (output 2 is only available for heating+cooling controller)NNo output2( For single output controller, choose code N)
RRelay output
VSSR Drive/Voltage pulse output
D4-20mA output
E0-10Vdc
F0-20mA
50-5Vdc
71-5Vdc
TTraic single phase zero-crossing trigger
ARelay output, for motor valve reverse act control
5: Alarm11 alarm
22 alarm
6:Power supply9685-265Vac
2424Vac/dc
7:PV/SV re-transmissionNNo re-transmission function
A4-20mA re-transmission via OP2
B0-20mA re-transmission via OP2
E0-10Vdc re-transmission via OP2
F4-20mA re-transmission via AU3
G0-20mA re-transmission via AU3
K0-10Vdc re-transmission via AU3
8:RS-485 CommunicationNNo communication feature
KRS-485 modbus RTU communication
9: AUX power sourceNNo aux power
A24Vdc isolated
B24Vdc grounded
C12Vdc isolated
D12Vdc grounded
10:Position feedback (analong feedback input from INP2)NNo position feedback
A4-20mA
B0-20mA
C0-5Vdc/potentiomter
D1-5Vdc
E0-10Vdc
11:Remote SV settingNNo remote SV feature
A4-20mA via INP2
B0-20mA via INP2
C0-5Vdc via INP2
D1-5Vdc via INP2
E0-10Vdc via INP2
F4-20mA via INP3
G0-20mA via INP3
H0-5Vdc via INP2
J1-5Vdc via INP3
K0-10Vdc via INP3
WD1/D2 terminals event input
12:Manual output% remote settingNNo remote SV feature
A4-20mA via INP2
B0-20mA via INP2
C0-5Vdc via INP2
E0-10Vdc via INP2
F4-20mA via INP3
G0-20mA via INP3
H0-5Vdc via INP3
K0-10Vdc via INP3